Sartorius PR6211 Tank and Hopper Load cell
The PR 6211 range of load cells is specially designed for weighing silos, tanks and process vessels.
The unique design principle facilitates a particularly compact construction and, as a result, the unit can be used even in restricted space conditions.
Features
The FlexLock installation kits counterbalance movements arising from mechanical or thermal expansion or contraction of the vessel or its supporting construction.
A particular design characteristic of some models is the thin-film or “splutter” technology.This enables an operating temperature of up to 180°C to be reached. In addition,the small construction has integrated overload protection of 500kg.
At the same time, this range distinguishes itself above all for its unmatched reliability, robustness and stability, which enable trouble-free operation without adjustment, year after year.
The hermetically sealed enclosure and special TPE cable allow the unit to be used even under extreme operating conditions in harsh production environments.
The entire measurement chain can be calibrated without the use of a reference weight.
Due to “matched output” technology, a damaged load cell can be exchanged without the need for re-calibration. This saves a tremendous amount of time during commissioning.
An explosion-proof (Ex) version of this range of load cells is also available, as an option, for use in intrinsically sage environments
Downloads - PR6211 Tank and Hopper Load cell
Accessories
- Sartorius PR 6011 Tank mounts for PR6211 loadcells
Optimal weighing performance for tanks and vessels.